Features:
– Simulated sine wave inverter
– Built-in AVR for voltage regulation
– Wide input voltage range: 90-280 VAC
– 12VDC available
– Overload and short circuit protection
– LCD display for comprehensive information
Specifications:
– MODEL Mecer IVR-1200LBK
– CAPACITY 1200 VA / 720 W
– POWER FACTOR 0.8
– Input Voltage range 90-280VAC
Line Mode:
– Output Voltage
– Bypass mode: 0utput voltage same as input voltage
– AVR mode: Output voltage = Input voltage 1.2 at Input voltage – Output Frequency Same as input
Battery Mode (BATTERIES NOT INCLUDED):
– Output Voltage 230Vac +/-10%
– Transfer Time 20ms typical
– Waveform Modified Sine-wave
Overload Capability:
– Bypass Mode (in VA and Watts) Load >110%+/-15% , alarm 5 mins then fault
– Load >130% +/-15%, fault immediately.
– AVR Mode (in VA and Watts)at Input voltage > 170VAC Load >100%+/-15%, go to bypass mode
– AVR Mode (in VA and Watts)at Input voltage < 170VAC Load >60%+/-15%, go to bypass mode
– Battery Mode (in W) Load>110% +/-15%, overload alarm for 15s, and then will switch to fault mode for 10s. Then unit will re-start for 5 times Load>120% +/-15% , fault & cut off O/P immediately.
Warning:
Charging and discharging a battery multiple times a day will significantly deteriorate its performance. Please note the limitations of each battery technology:
- Lead-acid batteries can only be discharged up to 50% before irreversible damage occurs.
- Gel lead-batteries can often be discharged up to 70% before irreversible damage occurs.
- Lithium batteries can be fully discharged if they are protected by a Battery Management System.
Due to the above limitations, loss of battery capacity is not covered under warranty.