title: Ubiquiti Unifi G3 Access Reader
date: 2025-06-24T11:04:24Z
modified: 2026-05-05T16:49:27Z
permalink: "https://tech.co.za/product/ubiquiti-unifi-access-access-reader-g3-ua-g3-w/"
type: product
status: publish
excerpt: "Ubiquiti's UA-G3-W is an IP55 tamper resistant access reader with speaker for single door access control indoors and outdoors. \\nPoE powers the unit, which connects to a UniFi Access Hub via PoE and can be unlocked using an NFC card or UniFi Identity Mobile App."
wpid: 543279
product_brand:
  - Ubiquiti
product_type:
  - simple
product_visibility:
  - featured
product_cat:
  - Security
featured_image: "https://tech.co.za/wp-content/uploads/2025/06/UA-G3-Wc.jpg"
---

| Dimensions | 93 x 40 x 36.5 mm |
| --- | --- |
| NFC Card & Keyfob Access | Yes |
| Apple/Google Wallet | Yes |
| Mobile Unlock | Yes |
| Handwave Request to Exit | Yes |
| NDAA Compliant | Yes |
| UL 294 Level | Destructive attack: Level I |
| Line security: Level I |  |
| Endurance: Level I |  |
| Standby power: Level I |  |
| Weatherproofing | IP55 |
| Hardware |  |
| Indoor and Outdoor Use | Yes |
| Ambient Operating Temperature | -30 to 45° C |
| Ambient Operating Humidity | 5 to 90% noncondensing |
| Networking Interface | (1) 10/100 MbE RJ45 port |
| Connectivity | BLE 4.1, NFC |
| Power Method | PoE |
| UL 294 Power-limited Class 2 PSU |  |
| UL 60950-1/62368-1 LPS/PS2 PSU |  |
| Max. Power Consumption | 5W |
| Supported Voltage Range | 48V DC |
| ESD/EMP Protection | Air: ±15kV, contact: ±8kV |
| Sensors | Proximity sensor |
| Speaker | ✓ |
| LEDs | R/G/B/W Learn More |
| Button | (1) Factory-reset |
| NFC Frequency | 13.56 MHz |
| NFC Read Range | < 30 mm (1.18”) |
| NFC Technology | ISO/IEC 14443A / 14443B / 15693 / 18092 (Ecma 340) |
| MIFARE Classic / MIFARE DESFIRE |  |
| Sony FeliCa™ (ID only) |  |
| NFC Forum tags T1T, T2T, T3T, T4T and T5T |  |
| ECP 2.0 |  |
| PoE Cabling Requirements | Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable. |
| UL 294 Statement | Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |